Hayward Super Pump 700 Manual: A Comprehensive Guide
Hayward’s detailed manual offers crucial installation, operation, and safety guidelines for the Super Pump 700 series, ensuring optimal performance and longevity of your pool’s pump.
Hayward’s Super Pump 700 series represents a significant advancement in pool pump technology, offering variable speed functionality for enhanced energy efficiency and quieter operation. This manual serves as a comprehensive resource for installers and end-users alike, detailing the proper procedures for installation, operation, maintenance, and troubleshooting.
Understanding the intricacies of this pump is vital, as incorrect installation or operation can lead to serious injury or void the warranty. The Super Pump 700 is designed for use with residential swimming pools and requires adherence to all local and national electrical codes; This guide emphasizes the importance of using genuine Hayward replacement parts to maintain performance and warranty validity. Furthermore, it highlights the availability of customer support for any questions or concerns.
Understanding the Super Pump 700 Series
The Hayward Super Pump 700 series encompasses various models, including SP2670010X15 and SP2670007X10, each tailored to specific pool sizes and filtration needs. These pumps feature a robust design with components like the pump housing and strainer, available in 1 ½” and 2” configurations (SPX1600AA, SPX1620AA).
Key components include gaskets (SPX1600T, SPX1600R) and seal assemblies (SPX1600TRA) crucial for leak-proof operation. The series’ variable speed capability allows for customized flow rates, reducing energy consumption and noise. Proper understanding of these components and their functions is essential for effective maintenance and repair. Always refer to the manual for specific model details and part numbers to ensure compatibility and maintain warranty coverage.
Key Features and Benefits
The Hayward Super Pump 700 boasts significant advantages, primarily its variable speed technology, leading to substantial energy savings and quieter operation. Its durable construction, utilizing components like the SPX1600AA and SPX1620AA pump housings, ensures long-term reliability.
The pump’s design simplifies maintenance, with easy access to the strainer basket for cleaning. Utilizing genuine Hayward replacement parts, like gaskets (SPX1600T, SPX1600R) and seal assemblies (SPX1600TRA), is vital to uphold warranty validity. Furthermore, the pump’s compatibility with BART transportation highlights Hayward’s community integration. These features combine to deliver efficient, cost-effective, and dependable pool circulation.

Installation Guide
Hayward’s manual stresses precise installation following defined instructions to avoid serious injury and to maintain the pump’s warranty coverage.
Pre-Installation Checklist
Before beginning installation of your Hayward Super Pump 700, a thorough checklist is essential for a smooth and safe process. Hayward’s manual emphasizes verifying all components are present, including the pump housing (SPX1600AA or SPX1620AA), gaskets (SPX1600T, SPX1600R), and potentially a seal assembly kit (SPX1600TRA).
Ensure the electrical supply matches the pump’s requirements and that a qualified electrician handles all electrical connections. Confirm adequate space around the pump for maintenance and access. Review local codes and regulations regarding pool pump installations. Finally, familiarize yourself with the manual’s safety warnings to prevent injury during the installation process. Proper preparation minimizes complications and ensures a reliable setup.
Step-by-Step Installation Process

The Hayward Super Pump 700 installation, as detailed in the manual, begins with mounting the pump on a stable, level surface. Next, carefully connect the suction and discharge piping, utilizing appropriate fittings and ensuring a watertight seal. Before electrical connection, verify proper grounding.
Install the strainer basket, ensuring it’s securely in place. The manual stresses the importance of using genuine Hayward replacement parts, like gaskets (SPX1600T, SPX1600R) to maintain warranty validity. Double-check all connections before proceeding. Finally, prime the pump according to the manual’s instructions to remove air from the system before initial startup. Following these steps guarantees a correct and efficient installation.
Electrical Connections and Safety
The Hayward Super Pump 700 manual emphatically prioritizes electrical safety. All connections must adhere to national and local electrical codes, performed by a qualified electrician. Before any work, disconnect power at the breaker. Ensure proper grounding to prevent electrical shock.
The manual warns against using extension cords and emphasizes the necessity of a dedicated circuit. Incorrect wiring can void the warranty and create hazardous conditions. Regularly inspect wiring for damage. Remember, using non-Hayward parts also voids the warranty. Prioritize safety throughout the electrical installation process, referencing the manual’s diagrams for correct wiring configurations.

Operation and Control
Hayward Super Pump 700 operation involves understanding the control panel, programming for efficiency, and utilizing variable speed functionality for optimized pool circulation.

Understanding the Control Panel
The Hayward Super Pump 700’s control panel is the central hub for managing pump operations. It allows users to adjust speed settings, program schedules, and monitor pump performance. Familiarize yourself with the buttons and display indicators to effectively control your pool’s circulation.
Key features typically include power on/off, speed control buttons (often with preset speeds), and a display showing pump speed (RPM) or flow rate. Some models offer advanced features like programmable timers for automated operation, allowing you to set specific run times based on your pool’s needs. Understanding these controls is vital for maximizing energy efficiency and maintaining optimal water quality. Refer to your specific model’s manual for detailed instructions on navigating the control panel’s functions.
Programming the Pump for Optimal Performance
To achieve peak efficiency and water clarity, programming your Hayward Super Pump 700 is essential. Utilize the control panel to create customized schedules tailored to your pool’s usage and filtration requirements. Consider running the pump at lower speeds for extended periods to save energy while maintaining adequate circulation.
Program different speeds for various times of the day – higher speeds for peak usage (swimming) and lower speeds overnight. Experiment with settings to find the optimal balance between energy consumption and water quality. Regularly review and adjust the schedule based on seasonal changes and pool activity. Proper programming maximizes the pump’s lifespan and minimizes operational costs.
Variable Speed Functionality Explained
The Hayward Super Pump 700’s variable speed technology offers significant advantages over traditional single-speed pumps. By adjusting the motor speed, you can precisely control water flow and optimize energy consumption. Lower speeds reduce noise levels and wear and tear on the pump components, extending its lifespan.
This functionality allows for customized filtration cycles, ensuring efficient debris removal without excessive energy use. The pump can operate at lower speeds for daily maintenance and ramp up to higher speeds for tasks like backwashing or spa jets. Utilizing variable speed capabilities translates to substantial cost savings and a quieter, more efficient pool operation.

Maintenance and Troubleshooting
Hayward’s manual details a regular maintenance schedule, cleaning procedures for the strainer basket, and winterization steps to ensure reliable pump operation.
Regular Maintenance Schedule
Hayward recommends a consistent maintenance routine for the Super Pump 700 to maximize its lifespan and efficiency. Inspect the pump regularly for leaks, unusual noises, or vibrations. The strainer basket should be cleaned frequently – ideally weekly, or more often depending on pool usage and environmental factors – to maintain optimal water flow.
Periodically check and clean the pump diffuser to ensure unobstructed flow. Annual inspection of the pump housing, gaskets (SPX1600T, SPX1600R), and seal assembly (SPX1600TRA) is advised, replacing worn parts as needed. Remember, using non-Hayward replacement parts will void the warranty. Following this schedule, as outlined in the manual, will help prevent costly repairs and ensure years of reliable service.
Cleaning the Strainer Basket
Regularly cleaning the Hayward Super Pump 700’s strainer basket is vital for maintaining optimal performance. Before cleaning, always turn off the pump to avoid any electrical hazards. Carefully remove the strainer basket cover, and lift out the basket. Discard any leaves, debris, or foreign objects collected within.
Inspect the basket for cracks or damage, replacing it if necessary – using genuine Hayward parts is crucial to avoid voiding your warranty. Rinse the basket thoroughly with a garden hose, ensuring all openings are clear. Reinstall the basket securely, and replace the cover, ensuring a tight seal. A clean strainer basket promotes efficient water flow and reduces strain on the pump.
Winterizing the Pump
Properly winterizing your Hayward Super Pump 700 is essential to prevent freeze damage. Begin by turning off power to the pump at the breaker. Drain all water from the pump housing, strainer pot, and plumbing lines. Remove the drain plugs to facilitate complete drainage.
Consider using a shop vacuum to remove any remaining water. Lubricate the pump lid O-ring with a silicone-based lubricant. Store the strainer basket indoors to prevent cracking. If possible, cover the pump with a protective cover. Following these steps will safeguard your investment and ensure a smooth start-up next season, maintaining your Hayward pump’s longevity.

Parts and Components
Hayward Super Pump 700 utilizes specific components like SPX1600AA housing, SPX1620AA strainers, and SPX1600T gaskets for optimal functionality and repair.
Pump Housing and Strainer Details (SPX1600AA, SPX1620AA)
The Hayward Super Pump 700’s housing is a critical component, available in two primary configurations: SPX1600AA and SPX1620AA. The SPX1600AA features a 1 ½ x 1 ½ inch connection, complete with integrated drain plugs for simplified maintenance and winterization. Conversely, the SPX1620AA offers a larger 2 x 2 inch connection, suited for systems requiring higher flow rates.
Both housings are constructed from durable materials designed to withstand pool chemical exposure and prolonged outdoor use. The inclusion of drain plugs facilitates easy water removal, preventing freezing damage during colder months. Selecting the correct housing size is paramount for ensuring compatibility with your existing plumbing and maximizing pump efficiency. Proper installation, as detailed in the manual, is essential for preventing leaks and maintaining optimal performance;
Gaskets and Seal Assembly (SPX1600T, SPX1600R, SPX1600TRA)
Maintaining a watertight seal is vital for the Hayward Super Pump 700’s efficient operation. Hayward provides specific gasket and seal components to ensure reliable performance. The SPX1600T is the housing gasket, crucial for preventing leaks between the pump housing sections. The SPX1600R designates the diffuser gasket, sealing the diffuser to the pump housing.
For comprehensive replacement, the SPX1600TRA kit includes both the housing and diffuser gaskets, alongside the essential seal assembly. Utilizing genuine Hayward parts, as emphasized in the manual, is paramount to uphold warranty validity and guarantee a proper fit. Regular inspection and replacement of these components, following the maintenance schedule, prevent costly repairs and ensure continued pump functionality.
Identifying Common Replacement Parts
The Hayward Super Pump 700 manual highlights frequently replaced components for streamlined maintenance. Beyond gaskets and seals, impeller replacements are common, restoring optimal flow rates. Strainer baskets (integrated within SPX1600AA and SPX1620AA pump housings) require periodic cleaning or replacement if damaged.
Diffusers, susceptible to wear, may need updating to maintain pressure. The manual stresses using genuine Hayward parts to avoid warranty issues. Knowing part numbers – like those for the pump housing (SPX1600AA, SPX1620AA) – simplifies ordering. Proactive identification of these parts, coupled with regular inspections, minimizes downtime and extends the pump’s lifespan, ensuring consistent pool operation as detailed in the comprehensive guide.

Troubleshooting Common Issues
Hayward’s manual assists in diagnosing problems like pump failure, reduced flow, or unusual noises, offering solutions to restore peak performance efficiently.
Pump Not Starting
If your Hayward Super Pump 700 fails to start, several factors could be at play. First, verify the power supply; ensure the circuit breaker hasn’t tripped and the pump is receiving voltage. Check all electrical connections, as loose wiring is a common culprit.
Next, inspect the pump’s control panel – is it displaying any error messages? Confirm the pump is properly programmed and not in a locked or off state. A clogged strainer basket restricts water flow, preventing startup, so clean it thoroughly.
Additionally, a faulty motor capacitor can hinder starting. If these steps don’t resolve the issue, consult the Hayward manual for detailed troubleshooting or contact customer support for assistance. Remember, using non-Hayward parts voids the warranty.
Low Flow Rate
Experiencing a low flow rate with your Hayward Super Pump 700 often indicates a restriction in the system. Begin by checking the strainer basket for debris – a clogged basket significantly reduces water intake. Inspect the skimmer and pump lid for obstructions.
Verify that all valves are fully open, including those on the filter and return lines. A dirty or clogged filter will dramatically decrease flow; backwash or clean the filter as needed. Also, examine the plumbing for any kinks or collapsed sections.
If the issue persists, the impeller might be damaged or worn, requiring inspection or replacement. Refer to the Hayward manual for specific guidance and part numbers. Remember, using genuine Hayward parts is crucial for maintaining warranty validity.
Unusual Noises During Operation
Hearing unusual noises from your Hayward Super Pump 700 demands immediate attention. A rattling sound could indicate debris lodged within the impeller housing; power down the pump and inspect for obstructions. Whining noises often suggest air entering the system – check all suction line connections for leaks and ensure proper priming.
Grinding sounds are a serious concern, potentially signaling a worn motor bearing or impeller damage. Consult the Hayward manual for troubleshooting steps and recommended repairs. A humming sound without water circulation may indicate a blocked impeller.
Always prioritize safety by disconnecting power before any inspection. Remember, using non-Hayward replacement parts will void your warranty, so utilize genuine components for repairs.

Warranty Information
Hayward’s warranty is voided by using non-genuine replacement parts; the manual details specific conditions and provides contact information for customer support inquiries.
Importance of Using Genuine Hayward Parts
Hayward emphatically stresses the critical importance of utilizing only genuine Hayward replacement parts for your Super Pump 700. The use of non-Hayward components immediately and completely voids the product’s warranty, leaving you responsible for any subsequent repair costs. Genuine parts are engineered to precise specifications, ensuring compatibility, optimal performance, and long-term reliability of the pump.
Aftermarket or imitation parts may appear similar, but often lack the quality control and materials necessary to withstand the demands of pool filtration systems. This can lead to premature failure, reduced efficiency, and potentially even damage to the pump itself. Protect your investment and maintain the integrity of your Hayward equipment by consistently choosing authentic Hayward parts as outlined in the manual.
Warranty Voiding Conditions
Several conditions will immediately invalidate your Hayward Super Pump 700 warranty. Most notably, the use of any non-Hayward replacement parts automatically voids coverage, regardless of the issue. Improper installation that deviates from the manual’s instructions is another key factor leading to warranty denial.
Furthermore, modifications to the pump, misuse, abuse, neglect, or operation outside of specified parameters will also void the warranty. Damage resulting from freezing, corrosion, or acts of nature are typically excluded. It’s crucial to retain proof of purchase and adhere strictly to the maintenance schedule detailed within the Hayward manual to ensure continued warranty protection.
Contacting Hayward Customer Support
For assistance with your Hayward Super Pump 700, reaching their customer support is vital. While specific contact details aren’t provided in the snippets, Hayward emphasizes the importance of contacting them directly for any questions or concerns regarding installation, operation, or warranty claims.
Refer to the official Hayward website (www.hayward.com) for the most up-to-date contact information, including phone numbers, email addresses, and potentially a live chat option. Ensure you have your pump’s model number (SP2670010X15 or SP2670007X10) and date of purchase readily available when contacting support to expedite the assistance process. Prompt communication can resolve issues efficiently.

Comparison: Super Pump 700 vs. Other Models
Hayward’s Super Pump 700 is frequently compared to models like SP2670010X15 and SP2670007X10, with INYOpools.com offering detailed comparisons for informed decisions.
Super Pump 700 vs SP2670010X15
Comparing the Hayward Super Pump 700 to the SP2670010X15 involves understanding their subtle differences within the same series. Both are variable speed pumps designed for energy efficiency and quieter operation, but the SP2670010X15 is a specific model within the Super Pump line.
The core functionality remains consistent – providing reliable circulation for your pool. However, specifications like horsepower and flow rate might vary slightly. The Hayward manual emphasizes the importance of selecting the correct pump size based on your pool’s volume and plumbing system.
INYOpools.com provides resources for direct comparison, highlighting potential differences in features and price points. Ultimately, consulting the Hayward documentation and considering your specific pool needs will guide you to the optimal choice. Using genuine Hayward parts is crucial for maintaining warranty validity.
Super Pump 700 vs SP2670007X10
The Hayward Super Pump 700 series encompasses various models, including the SP2670007X10. Both share the benefits of variable speed technology – reduced energy consumption and quieter operation compared to single-speed pumps. However, key distinctions exist, primarily in horsepower and flow rate capabilities.
The SP2670007X10 represents a specific configuration within the Super Pump family. Hayward’s manual stresses the importance of matching the pump’s capacity to your pool’s size and plumbing. INYOpools.com offers comparative details, assisting in identifying the ideal pump for your needs.
Careful consideration of these specifications, alongside the guidance provided in the Hayward owner’s manual, ensures optimal performance and longevity. Remember, utilizing non-Hayward replacement parts will immediately void your warranty.
Choosing the Right Pump for Your Pool
Selecting the appropriate Hayward Super Pump 700 model requires careful evaluation of your pool’s specific needs. The Hayward manual emphasizes matching pump capacity to pool volume and plumbing size for optimal efficiency; Consider factors like pool surface area, filtration system requirements, and desired water flow rates.
Comparing models like the SP2670010X15 and SP2670007X10, as detailed by INYOpools.com, highlights horsepower and flow rate differences. Prioritize energy efficiency by leveraging the variable speed functionality detailed within the owner’s manual.
Always adhere to the installation instructions outlined in the manual to avoid voiding the warranty. Using genuine Hayward parts is crucial for maintaining performance and upholding warranty coverage.